Boiler Accessories

Boiler Accessories

Improve energy efficiency and reduce cost with the proper boiler accessories to keep your boiler operating at peak efficiency.

Condensate Recovery

Cleaver-Brooks Condensate Return System

Cleaver-Brooks condensate return system

Returns condensate back to the system to improve energy efficiency and reduce chemical, make-up water and sewer disposal costs, while helping meet environmental regulations.

Design
Simplex or Duplex; single or 3-phase
Size range
10, 15, 25, 35 gallon capacity
Use
Steam and hot water applications

Fabtek Condensate Return System

Fabtek condensate return system

All Duplex and Simplex units include a 304SS tank, SS vertical flange-mounted centrifugal pumps, NEMA 1 float switch (Simplex) or mechanical alternator (Duplex), and an SS sight-gauge assembly. Pumps and tanks are interchangeable, and the 304SS tank carries a 20-year warranty against corrosion failure.

Design
Simplex or Duplex
Size range
6–150 gpm (2,500–37,500 PPH)

Energy Recovery

Cleaver-Brooks Heat Recovery Solutions

Cleaver-Brooks economizer

Reduce costs and environmental impact by recovering waste heat or steam and reusing it elsewhere in the system.

  • Stack economizer — recover heat from flue gases that would otherwise be wasted and save up to 5% on your fuel bill. For high make-up systems, a two-stage economizer adds a second stage to preheat deaerator make-up water, raising boiler efficiency up to 95%.
  • Condensing economizer — save on fuel and increase fuel-to-steam efficiency up to 90%.

Cannon Boiler Works Economizers

Cannon Boiler Works economizers

Three parameters determine the best heat-recovery product for you: fuel type, acceptable exhaust backpressure, and inlet water temperature.

  • Feedwater Heater — small boilers, natural gas, non-condensing flue gas. Inlet 150–250°F.
  • Gas Condensing Water Heater — small and large systems, natural gas, condensing flue gas. Inlet 40–150°F.
  • Heavy Duty Economizer — large systems burning dirty fuels, non-condensing flue gas. Inlet 200°F minimum.
  • On-Demand Economizer — fits where others won’t; natural gas, condensing flue gas. Inlet 40–150°F.
  • Dual Stage Economizer — heats two streams with one economizer; small and large systems, condensing or non-condensing. Inlet 40–250°F.

Exhaust Solutions

Exhaust and venting products — including AMPCO stacks, Jeremias venting, and U.S. Draft dampers — are covered on our dedicated Exhaust Solutions page.

Ready to discuss your boiler room?

Contact